Dell 403-BBUI 9440-8I Tri-Mode PCI-E Raid Controller 12GBPS SAS/SATA/Nvme

403-BBUI
Hover on image to enlarge

Brief Overview of 403-BBUI

Tri-Mode PCI-E Raid Controller Dell 403-BBUI 9440-8I 12GBPS SAS/SATA/Nvme. New Sealed in Box (NIB) with 3-Year Replacement Warranty
QR Code of Dell 403-BBUI 9440-8I Tri-Mode PCI-E Raid Controller 12GBPS SAS/SATA/Nvme
Contact us for a price
Ask a question
Additional 7% discount at checkout
SKU/MPN403-BBUIAvailability✅ In StockProcessing TimeUsually ships same day ManufacturerDell Product/Item ConditionNew Sealed in Box (NIB) ServerOrbit Replacement WarrantySix-Month (180 Days)
Our Advantages
  • Free Ground Shipping 
  • — Min. 6-month Replacement Warranty
  • — Genuine/Authentic Products  
  • — Easy Return and Exchange
  • — Different Payment Methods
  • — Best Price
  • — We Guarantee Price Matching
  • — Tax-Exempt Facilities
  • — 24/7 Live Chat, Phone Support 
Payment Options
  • — Visa, MasterCard, Discover, and Amex
  • — JCB, Diners Club, UnionPay
  • — PayPal, ACH/Wire Transfer
  • — Apple Pay, Amazon Pay, Google Pay
  • — Buy Now, Pay Later - Affirm, Afterpay
  • — GOV/EDU/Institutions PO's Accepted 
  • — Invoices
Delivery
  • — Deliver Anywhere
  • — Express Delivery in the USA and Worldwide
  • — Ship to -APO -FPO
  • For USA - Free Ground Shipping
  • — Worldwide - from $30

Same product also available in:

Description

Interface: PCI-E

The Dell 9440-8I Raid Controller is equipped with a PCI-E interface, which provides users with numerous benefits and ensures seamless data transfer and storage management. In this section, we will delve into the importance of the PCI-E interface and its advantages for users.

High-Speed Data Transfer

One of the primary benefits of the PCI-E interface is its ability to deliver high-speed data transfer rates. With a maximum transfer rate of up to 12Gbps, the Dell 9440-8I Raid Controller ensures lightning-fast data transmission between the controller and connected drives. This high-speed transfer is crucial for users who handle large amounts of data or work with resource-intensive applications. It enables them to optimize their workflow and significantly reduce the time required for data backups, system restores, and other storage-related operations.

Improved System Performance

By utilizing the PCI-E interface, the Dell 9440-8I Raid Controller enhances overall system performance. The increased bandwidth provided by PCI-E allows for faster access to data, resulting in improved read and write speeds. This boost in performance is particularly beneficial for tasks that involve heavy data processing, such as video editing, database management, and virtualization. Users can experience

and enjoy a more responsive computing environment, enhancing productivity and efficiency.

Scalability and Future-Proofing

The PCI-E interface offers excellent scalability options for users. It allows for easy expansion of storage capacity by supporting additional RAID controllers or adding more drives to the existing setup. This scalability ensures that users can adapt their storage infrastructure to meet their evolving needs without having to invest in a new controller or undergo complex system reconfigurations. By future-proofing their storage solutions, users can save costs in the long run and ensure compatibility with upcoming technologies.

Compatibility with Modern Systems

PCI-E has become the standard interface for modern computer systems, ensuring compatibility with a wide range of hardware configurations. The Dell 9440-8I Raid Controller's PCI-E interface makes it compatible with most contemporary servers, workstations, and storage devices. This compatibility ensures that users can integrate the controller seamlessly into their existing infrastructure without any compatibility issues or the need for additional adapters. It simplifies the installation process and reduces the chances of encountering compatibility-related headaches.

Hot-Swapping Capabilities

Another advantage of the PCI-E interface is its hot-swapping capabilities. Hot-swapping allows users to replace or add drives to their RAID configuration without having to power down the system. This feature is particularly useful in scenarios where downtime is not an option, such as in mission-critical environments or businesses that rely heavily on continuous data availability. With hot-swapping support, users can perform hardware maintenance or upgrades on-the-fly, minimizing disruptions and ensuring uninterrupted operations.

Raid Levels Supported: RAID 0, RAID 1, RAID 10, RAID 5, RAID 50, RAID 6, RAID 60

The Dell 9440-8I Raid Controller supports a wide range of RAID levels, offering users flexibility and reliability in their storage configurations. In this section, we will explore the benefits and importance of these RAID levels and how they cater to different user requirements.

RAID 0: Enhanced Performance

RAID 0, also known as striping, combines multiple drives into a single logical unit and splits data across them. This configuration improves performance by distributing read and write operations across multiple drives simultaneously. By utilizing parallel processing, RAID 0 offers significantly faster data transfer speeds compared to a single drive setup. It is ideal for tasks that require high-speed data access, such as video editing, gaming, and real-time data analysis.

RAID 1: Data Redundancy

RAID 1, or mirroring, duplicates data across multiple drives, providing redundancy and data protection. In this configuration, every write operation is simultaneously mirrored onto two drives, ensuring that if one drive fails, the data remains intact on the other drive. RAID 1 offers enhanced data integrity and fault tolerance, making it suitable for critical applications where data loss is not an option. While it does not provide the same performance benefits as RAID 0, RAID 1 ensures data reliability and allows for quick recovery in case of drive failures.

RAID 10: Performance and Redundancy

RAID 10 combines the benefits of RAID 0 and RAID 1 by striping data across mirrored pairs of drives. This configuration offers both improved performance and data redundancy. By utilizing a minimum of four drives, RAID 10 provides fault tolerance against drive failures while delivering enhanced read and write speeds. It is suitable for applications that require high performance and maximum data protection, such as database servers and file servers.

RAID 5: Balancing Performance and Redundancy

RAID 5 utilizes striping with parity to achieve a balance between performance and redundancy. It distributes data and parity information across multiple drives, allowing for increased read speeds and fault tolerance. In the event of a single drive failure, RAID 5 can reconstruct the lost data using the parity information stored on the remaining drives. This level of fault tolerance makes RAID 5 suitable for environments where cost-effective redundancy is required without sacrificing too much storage capacity.

RAID 50: Enhanced Performance and Redundancy

RAID 50 combines the performance benefits of RAID 0 with the fault tolerance of RAID 5. It stripes data across multiple RAID 5 arrays, offering improved read and write speeds while providing redundancy against drive failures. RAID 50 is well-suited for applications that demand high performance, such as video editing or virtualization, while also requiring a high level of data protection.

RAID 6: Dual Parity for Enhanced Fault Tolerance

RAID 6 builds upon RAID 5 by adding an additional parity block for increased fault tolerance. This means that RAID 6 can withstand the failure of two drives simultaneously without losing any data. By using dual parity, RAID 6 provides an extra layer of protection against drive failures, making it ideal for environments where data integrity is critical. However, it should be noted that RAID 6 incurs a slight performance penalty compared to RAID 5 due to the additional parity calculations.

RAID 60: Performance and Dual Parity

RAID 60 combines the performance advantages of RAID 0 with the dual parity protection of RAID 6. It stripes data across multiple RAID 6 arrays, offering enhanced read and write speeds while providing fault tolerance against multiple drive failures. RAID 60 is suitable for scenarios that demand high performance and require a high level of data redundancy, such as large-scale database systems or enterprise storage solutions.

Data Transfer Rate: 12Gbps

The Dell 9440-8I Raid Controller boasts an impressive data transfer rate of up to 12Gbps. In this section, we will discuss the benefits and importance of this high-speed data transfer capability for users.

Optimized Workflow

The 12Gbps data transfer rate offered by the Dell 9440-8I Raid Controller significantly enhances workflow efficiency. With faster data transfer speeds, users can experience reduced waiting times when performing tasks such as file transfers, system backups, or running resource-intensive applications. The increased throughput ensures that data can be processed and accessed quickly, allowing users to complete their tasks in less time and improving overall productivity.

Seamless Data-intensive Operations

For users dealing with data-intensive operations, such as video editing or data analytics, the 12Gbps transfer rate provided by the Dell 9440-8I Raid Controller proves to be crucial. These operations involve handling large file sizes or processing massive datasets, which demand high-speed data access. The controller's ability to transfer data at 12Gbps enables seamless playback of high-definition videos, faster rendering times, and quicker analysis of vast amounts of data. It ensures that users can work with resource-intensive applications without experiencing bottlenecks or slowdowns.

Reduced Latency

Latency can significantly impact system performance and user experience, particularly in demanding applications. The 12Gbps data transfer rate offered by the Dell 9440-8I Raid Controller helps minimize latency by allowing for rapid data retrieval and processing. Lower latency means reduced delays when accessing files or executing commands, resulting in a more responsive computing environment. This is particularly important in scenarios where real-time data processing or quick access to critical information is required.

Future-Proofing

The 12Gbps data transfer rate is future-proofing the storage infrastructure. As technology advances and the size of datasets continues to grow, faster data transfer speeds become essential for handling the increasing demands of modern applications. By investing in a RAID controller that supports a high-speed transfer rate like 12Gbps, users can ensure that their storage infrastructure remains compatible with future technologies and can handle the ever-increasing data requirements.

Compatibility with High-Speed Storage Devices

The 12Gbps data transfer rate supported by the Dell 9440-8I Raid Controller enables compatibility with high-speed storage devices such as solid-state drives (SSDs) and NVMe drives. These storage devices can take full advantage of the controller's high transfer rate, allowing for maximum performance and efficiency. Users can leverage the benefits of these advanced storage technologies, such as faster boot times, reduced application load times, and improved system responsiveness.

Supported Drive Types: SAS, SATA, NVMe

The Dell 9440-8I Raid Controller supports a wide range of drive types, including SAS (Serial Attached SCSI), SATA (Serial ATA), and NVMe (Non-Volatile Memory Express). This extensive compatibility offers users flexibility in choosing the most suitable drive type for their specific requirements. In this section, we will explore the benefits and importance of each supported drive type.

SAS (Serial Attached SCSI)

SAS drives are known for their high performance, reliability, and scalability. They are designed for enterprise applications that demand fast data access and require high levels of fault tolerance. The Dell 9440-8I Raid Controller's support for SAS drives allows users to take advantage of their superior performance capabilities. SAS drives offer faster data transfer rates, lower latency, and better error correction mechanisms compared to SATA drives. They are ideal for environments that require high-performance storage solutions, such as database servers or mission-critical applications.

SATA (Serial ATA)

SATA drives are widely used in consumer-grade applications due to their cost-effectiveness and ease of use. The Dell 9440-8I Raid Controller's support for SATA drives provides users with a more affordable storage option without sacrificing reliability. SATA drives offer ample storage capacities at lower price points, making them suitable for applications that prioritize cost-efficiency over maximum performance. They are commonly used in desktop computers, small business servers, and personal storage solutions.

NVMe (Non-Volatile Memory Express)

NVMe drives represent the latest advancement in storage technology, offering unparalleled performance and low latency. The Dell 9440-8I Raid Controller's support for NVMe drives enables users to harness the full potential of these high-speed storage devices. NVMe drives leverage the PCI-E interface to deliver significantly faster data transfer rates and reduced latencycompared to traditional SATA or SAS drives. They are particularly beneficial for applications that demand lightning-fast storage, such as high-end gaming, 3D modeling, or real-time data processing. By utilizing NVMe drives, users can experience blazing-fast boot times, quick application launches, and improved overall system performance.

Flexibility and Scalability

The support for multiple drive types offered by the Dell 9440-8I Raid Controller provides users with flexibility and scalability in their storage configurations. Depending on their specific needs, users can choose the drive type that best suits their requirements in terms of performance, capacity, and cost. Additionally, the ability to mix different drive types within the same RAID setup enables users to optimize their storage solutions according to their unique workload characteristics. This flexibility ensures that users can tailor their storage infrastructure to meet their current and future needs without constraints.

Compatible with Existing Drives

The Dell 9440-8I Raid Controller's support for SAS, SATA, and NVMe drives ensures compatibility with existing drives that users may already have in their infrastructure. Whether the user wants to integrate new drives or leverage their existing storage devices, the controller provides a seamless solution. This compatibility eliminates the need to replace all existing drives when upgrading or expanding storage capacity, saving costs and simplifying the migration process.

In conclusion, the Dell 9440-8I Raid Controller offers a range of features that enhance data transfer speeds, improve system performance, provide fault tolerance, and offer compatibility with various drive types. The PCI-E interface ensures high-speed data transfer rates, providing users with faster access to their data and optimizing workflow efficiency. The support for multiple RAID levels, including RAID 0, RAID 1, RAID 10, RAID 5, RAID 50, RAID 6, and RAID 60, allows users to choose the level of performance and redundancy that best suits their needs. The 12Gbps data transfer rate ensures seamless data-intensive operations, reduced latency, and future-proofing of the storage infrastructure. Lastly, the support for SAS, SATA, and NVMe drives provides users with flexibility, scalability, and compatibility with existing drives. With the Dell 9440-8I Raid Controller, users can build a robust and efficient storage solution tailored to their specific requirements.