Your go-to destination for cutting-edge server products

9/9
Enhanced Search
Enhanced Search
By Manufacturer
By Price

$  –  $

  • $0
  • $409.44
By Condition

Flash Backed Write Cache

An Extra 7% Discount at Checkout
$83.70 $55.00
Quote
SKU/MPN726795-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Product/Item ConditionNew (System) Pull ServerOrbit Replacement WarrantySix-Month (180 Days)
An Extra 7% Discount at Checkout
$116.10 $74.00
Quote
SKU/MPN631667-B21Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer WarrantyNone Product/Item ConditionFactory-Sealed New in Original Box (FSB)
An Extra 7% Discount at Checkout
$44.55 $36.00
Quote
SKU/MPN534562-B21Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty1 Year Warranty Original Brand Product/Item ConditionNew (System) Pull
An Extra 7% Discount at Checkout
$83.70 $71.00
Quote
SKU/MPN750000-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Product/Item ConditionNew Sealed in Box (NIB) ServerOrbit Replacement WarrantySix-Month (180 Days)
An Extra 7% Discount at Checkout
$85.00 $46.00
Quote
SKU/MPN766205-B21Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty1 Year Warranty Original Brand Product/Item ConditionNew (System) Pull
An Extra 7% Discount at Checkout
Contact us for a price
SKU/MPN631679-B21Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty3 Years from the Original Brand Product/Item ConditionFactory-Sealed New in Original Box (FSB)
An Extra 7% Discount at Checkout
$606.15 $409.44
Quote
SKU/MPN633541-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty3 Years from the Original Brand Product/Item ConditionFactory-Sealed New in Original Box (FSB)
An Extra 7% Discount at Checkout
$59.40 $31.00
Quote
SKU/MPN633541-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Product/Item ConditionNew (System) Pull ServerOrbit Replacement WarrantySix-Month (180 Days)
An Extra 7% Discount at Checkout
$60.00 $31.00
Quote
SKU/MPN610673-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty1 Year Warranty Original Brand Product/Item ConditionNew (System) Pull
An Extra 7% Discount at Checkout
$60.00 $29.00
Quote
SKU/MPN633542-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty1 Year Warranty Original Brand Product/Item ConditionNew (System) Pull
An Extra 7% Discount at Checkout
$75.00 $31.00
Quote
SKU/MPN610672-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty1 Year Warranty Original Brand Product/Item ConditionNew (System) Pull
An Extra 7% Discount at Checkout
$79.00 $29.00
Quote
SKU/MPN610674-001Availability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer Warranty1 Year Warranty Original Brand Product/Item ConditionNew (System) Pull

Smart Array Flash Backed Write Cache Overview

Smart Array Flash Backed Write Cache (FBWC) is an essential component for enhancing the performance and reliability of server storage systems. Often found in enterprise-level server environments, it ensures faster data access and greater data protection. This category includes various FBWC products, designed to optimize data writing performance and safeguard data integrity in case of power loss or other interruptions. Below, we explore the components, benefits, installation, and compatibility of Smart Array FBWC solutions.

What is Smart Array Flash Backed Write Cache?

Smart Array Flash Backed Write Cache is a high-performance memory solution that serves as a temporary storage buffer for write operations in RAID (Redundant Array of Independent Disks) systems. It significantly improves the speed of write operations, especially in systems that handle large volumes of data. The FBWC module uses flash memory to store write data temporarily, ensuring it is not lost even if the system experiences power failure. This feature helps maintain the reliability and performance of enterprise storage systems by ensuring that data is safely written to disk once the power is restored.

Key Features

Smart Array FBWC products offer a range of features that contribute to their reliability and performance:

  • Power Loss Protection: With flash-backed memory, data can be retained for a sufficient period even during power outages. This ensures no data loss occurs while waiting for a backup power source or the return of power.
  • Enhanced Write Performance: By temporarily storing write data in high-speed flash memory, FBWC modules reduce the write latency, leading to improved overall system performance.
  • RAID Integration: Smart Array FBWC works seamlessly with RAID controllers, enhancing both RAID 1 (mirroring) and RAID 5 (parity) configurations for optimal data redundancy and access speed.
  • Data Integrity: Data written into the cache is protected until it is committed to disk, preventing data corruption during power loss or system crashes.

Smart Array Flash Backed Write Cache

Smart Array Flash Backed Write Cache is ideal for use in mission-critical environments where both performance and data integrity are essential. Common applications include:

  • Enterprise Servers: For businesses with high transaction volumes and large data sets, FBWC offers enhanced performance and data reliability.
  • Database Servers: Servers hosting relational databases or applications that involve frequent write operations can benefit from improved write speeds and protection against data loss.
  • Virtualized Environments: In virtualized environments, where many virtual machines share storage resources, FBWC ensures fast write operations and minimizes latency.

Advantages

Improved Performance

One of the most significant advantages of Flash Backed Write Cache is the substantial improvement in write performance. The temporary storage of write data in flash memory allows servers to process write operations much faster, which directly enhances the overall system performance. In particular, applications and workloads that involve intensive disk writes, such as databases and virtual machines, benefit greatly from this feature.

Data Protection

Power loss or unexpected system shutdowns can result in data corruption or loss, especially when write operations are in progress. FBWC mitigates this risk by temporarily storing write operations in a flash memory buffer. When power is restored, data is safely written to the disk, preventing the loss of critical information and ensuring system reliability.

How Does Smart Array Flash Backed Write Cache Work?

The working principle behind Smart Array Flash Backed Write Cache is straightforward but effective. When a write operation is initiated, the data is first written to the flash memory on the FBWC module instead of directly writing it to disk. This buffer temporarily holds the data, allowing the server to continue with other tasks without waiting for the write operation to complete. Once the system has sufficient power or resources, the data is written to disk. In the event of a power failure or system crash, the data held in the cache is preserved in flash memory until the system recovers, ensuring no data is lost.

Smart Array Flash Backed Write Cache Compatibility

When selecting a Smart Array FBWC product, compatibility with the RAID controller and the server environment is essential. Most modern server systems from leading manufacturers like HP, Dell, and Lenovo are compatible with FBWC solutions, but it’s important to verify specific model support. FBWC solutions are often designed to integrate seamlessly with various RAID controllers, providing an additional layer of protection and performance enhancement to the storage system.

Compatibility with RAID Controllers

Smart Array Flash Backed Write Cache is designed to work specifically with RAID controllers to ensure optimal performance. Different RAID levels (such as RAID 1, RAID 5, or RAID 10) can take advantage of the enhanced write capabilities provided by FBWC. Depending on the server’s RAID configuration, the Smart Array FBWC module helps in optimizing both read and write operations, improving overall efficiency.

System Compatibility

In addition to RAID controller compatibility, Smart Array FBWC modules are compatible with a wide range of enterprise servers and storage systems. These modules integrate smoothly into systems designed for high-demand environments, such as large-scale data centers, cloud infrastructure, and enterprise IT operations. Users should always consult compatibility charts provided by the manufacturer to ensure the correct configuration for their specific needs.

Supported Servers

Smart Array Flash Backed Write Cache solutions support various server models from leading manufacturers such as:

  • HP ProLiant Servers: HP offers a variety of server systems equipped with RAID controllers that support FBWC technology, ensuring high-performance data handling for critical workloads.
  • Dell PowerEdge Servers: Dell's PowerEdge range includes servers that are optimized for Smart Array FBWC, allowing for enhanced data write operations and reliability.
  • Lenovo ThinkSystem Servers: Lenovo servers are equipped with Smart Array RAID controllers that support FBWC to improve system performance and data safety.

Smart Array Flash Backed Write Cache vs. Battery-Backed Write Cache

Flash Backed Write Cache offers several advantages over traditional battery-backed solutions. While both systems provide data protection during power loss, Flash Backed Write Cache is typically faster, more reliable, and less prone to issues associated with battery degradation. Additionally, FBWC modules tend to have longer lifespans and do not require frequent battery replacements, making them a more convenient and cost-effective solution for long-term use.

Advantages of Flash Backed Write Cache

  • Longer Lifespan: Flash memory is more durable than batteries and has a significantly longer lifespan.
  • Faster Performance: Flash memory provides faster data access compared to traditional batteries, enhancing write performance.
  • No Battery Maintenance: Unlike battery-backed systems, FBWC does not require regular battery replacements, reducing maintenance efforts.

Battery-Backed Write Cache

While battery-backed write cache solutions also offer power loss protection, they are typically slower than flash-based solutions and require regular battery replacements. As battery capacity degrades over time, so does the performance of the cache. Battery-backed write cache also has a shorter operational lifespan than FBWC solutions, which are less dependent on wear and tear.