Your go-to destination for cutting-edge server products

AH233-2002A HPE Internal Lower Fan Power Cable Assembly for ProLiant DL785 G5

AH233-2002A
* Product may have slight variations vs. image
Hover on image to enlarge

Brief Overview of AH233-2002A

HPE AH233-2002A Internal Lower Fan Power Cable Assembly for ProLiant DL785 G5. Excellent Refurbished with 1 year replacement warranty

$63.45
$47.00
You save: $16.45 (26%)
Ask a question
Price in points: 47 points
+
Quote

Additional 7% discount at checkout

SKU/MPNAH233-2002AAvailability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Product/Item ConditionExcellent Refurbished ServerOrbit Replacement Warranty1 Year Warranty
Google Top Quality Store Customer Reviews
Our Advantages
Payment Options
  • — Visa, MasterCard, Discover, and Amex
  • — JCB, Diners Club, UnionPay
  • — PayPal, ACH/Bank Transfer (11% Off)
  • — Apple Pay, Amazon Pay, Google Pay
  • — Buy Now, Pay Later - Affirm, Afterpay
  • — GOV/EDU/Institutions PO's Accepted 
  • — Invoices
Delivery
  • — Deliver Anywhere
  • — Express Delivery in the USA and Worldwide
  • — Ship to -APO -FPO
  • For USA - Free Ground Shipping
  • — Worldwide - from $30
Description

Product Overview

The HP Internal Lower Fan Power Cable Assembly, designed specifically for the ProLiant DL785 G5 server, ensures reliable performance and seamless connectivity for data center environments. Built with durability and efficiency in mind, this cable provides stable power transmission, reducing downtime and maximizing server functionality.

General Information

  • Product Type: Internal Power Cable
  • Part Number: AH233-2002A
  • Manufacturer: Hewlett-Packard (HP)
  • Compatibility: ProLiant DL785 G5

Key Features of AH233-2002A

  • High-quality construction for long-lasting performance
  • Designed to deliver consistent power to the server fan system
  • Supports stable airflow and cooling efficiency
  • Optimized for HP ProLiant DL785 G5 infrastructure
  • Minimizes risks of overheating with reliable fan power distribution

Benefits of Using This Power Cable

  • Improved cooling system stability in enterprise servers
  • Reduces operational interruptions due to power fluctuations
  • Easy integration with compatible HP systems
  • Maintains the longevity of server hardware

Applications and Usage

This internal lower fan power cable is essential for IT professionals, system administrators, and enterprises that rely on consistent server performance. It plays a critical role in powering the fan assemblies, maintaining airflow management, and preventing system overheating during heavy workloads.

Technical Specifications

  • Model: AH233-2002A
  • Type: Fan Power Cable Assembly
  • Server Fit: ProLiant DL785 G5
  • Build Quality: High-durability wiring with precision connectors

HPE AH233-2002A Internal Lower Fan Power Cable Assembly — Detailed category description

The HPE AH233-2002A Internal Lower Fan Power Cable Assembly is a precision-engineered internal harness specifically intended for cooling subsystem connectivity in legacy HPE ProLiant DL785 G5 servers. This category encompasses OEM replacement assemblies, service spare equivalents, and verified aftermarket alternatives designed to restore or maintain lower-fan power and control signal integrity. The following content expands on technical specifications, compatibility nuances, procurement strategies, installation procedures, testing and validation, maintenance cycles, failure modes, comparative evaluations, use cases, spares planning, compliance considerations, and search-optimized buying terms to help IT teams, system integrators, refurbishers, and procurement professionals find and select the correct cable assembly.

Mechanical characteristics

  • Connector geometry: OEM keyed connectors that physically match HPE fan header housings to prevent misinsertion and mechanical stress.
  • Overall harness geometry: Optimized lengths and bend radii that route under the lower fan tray and along chassis channels without impeding airflow.
  • Sleeving and bundling: Durable braided or heat-shrink sleeving over bundled conductors to protect against abrasion and chafing during installation and servicing.
  • Mounting aides: Integrated tie-point loops and molded anchors to secure the harness to chassis clips or cable paths defined by HPE’s service manual.

Electrical characteristics and signal support

  • Conductor AWG: Appropriately sized for continuous fan motor current and short transient loads.
  • Power rails: Support for low-voltage DC fan power rails typical of ProLiant systems (nominal fan voltages and allowed tolerances per HPE spec).
  • Control and monitoring lines: Inclusion of tachometer (RPM) return lines, and where applicable, PWM/tach pairing to preserve system-level fan speed control and telemetry.
  • Contact finish: Corrosion-resistant plating such as tin or gold flash applied to contact surfaces to maintain low resistance and reliable telemetry over many cycles.

Cross-compatibility considerations

Some Gen5-era HPE servers may share similar fan header pinouts or connector housings. However, assuming interchangeability can lead to mis-wiring, incorrect tachometer polling, or physical fit issues. Always match these critical attributes:

  • Physical connector keying and latch arrangement.
  • Pinout order (power, ground, tachometer, PWM/control) — verify against the server's engineering diagram.
  • Length and routing — ensure alternative harness will reach both endpoints without stressing connectors.
  • Shielding and sleeve construction if the server operates in noisy electrical environments or near high-frequency components.

Advantages of OEM AH233-2002A

  • Guaranteed fit and mapping: OEM parts are manufactured to the original HPE drawing and validated against the DL785 G5 chassis.
  • Material traceability: OEM supply chain documentation often details materials and plating processes used, aiding in long-term failure analysis.
  • Supportability: OEM parts may be referenced in official HPE service documents, simplifying replacement instructions and troubleshooting flows.

Procurement checklist and smart ordering practices

Reduce procurement friction by following a structured checklist. This helps prevent mistake orders, speeds up receiving inspection, and reduces MTTR when parts fail.

Pre-order validation

  • Confirm the HPE OEM part number: AH233-2002A.
  • Retrieve the server's spare part list from the HPE parts catalog or service manual.
  • If buying aftermarket, request datasheets, pictures of connectors, and a pinout diagram.
  • Verify supplier return policy and warranty terms before placing an order.

Receiving inspection

  • Immediately photograph the supplied cable against the original to confirm match.
  • Inspect connectors for proper plating, latch security, and correct pin orientation.
  • Confirm cable length and sleeving match expectations and will route without obstruction.
  • Tag inventory with purchase date, vendor, and part number for traceability.

Preparation and safety

  • Power down and disconnect the server from AC power and redundant power sources if applicable.
  • Observe ESD procedures: wear a grounded wrist strap and work on an anti-static mat.
  • Gather tools: small flat-blade for connector disengagement, zip ties, labels, cable ties, and a camera for documentation.

Verification and validation

  • Monitor fan RPMs and thermal sensors through iLO, system event logs, or OS-level monitoring.
  • Run a short thermal load or a hardware diagnostics routine to verify no erroneous fan faults appear.
  • Confirm the chassis airflow is unobstructed and that cable routing does not interfere with airflow baffles or other subassemblies.

Common symptoms indicating harness issues

  • Fans not spinning or spinning at incorrect speeds.
  • Intermittent fan alarms that clear when the server is touched or cables are re-seated (sign of intermittent connection).
  • Multiple fans reporting identical faults simultaneously (could indicate a harness routing common power or ground).

Diagnostic sequence

  1. Visual inspection for chafing, discoloration, or burnt insulation.
  2. Reseat both ends of the harness and confirm positive mechanical latching.
  3. Swap in a known-good harness to test whether the issue follows the cable.
  4. If possible, measure continuity on suspect lines or use a service meter to confirm voltage presence at the fan connector when the server is powered.
  5. Inspect fan assembly connectors and the motherboard/backplane header for bent pins or evidence of overheating.

Inspection cadence

  • Quarterly visual inspections for large-scale deployments or high-utilization hardware.
  • Biannual checks for lightly loaded or lab systems.
  • Detailed inspection when performing other chassis-level maintenance or upgrades.

Spares strategy

  • Maintain a minimum of one spare AH233-2002A per rack containing multiple DL785 G5 servers.
  • For distributed critical systems, keep spares in strategic locations (network closets, central stores) to reduce MTTR.
  • Record spares usage in CMDB or asset management systems for budget forecasting and re-ordering.

Impact on thermal management and operational reliability

A functional lower fan harness ensures that the thermal control loop of the server behaves as designed. Properly routed and electrically sound harnesses allow PWM and tachometer signals to enable nuanced fan speed modulation tied to CPU, memory, and ambient conditions, thereby finely balancing acoustics, power draw, and thermal safety.

  • Accurate telemetry: Tachometer lines permit the BMC to read exact RPMs and trigger appropriate fan-policied responses.
  • Noise and power optimization: Reliable PWM control lets fans run at lower speeds during light loads, reducing power and acoustic footprint.
  • Avoiding thermal throttling: Faulty harnesses can cause false fan errors that lead to conservative thermal throttling or shutdowns — a direct production impact avoided by correct parts.

Regulatory, safety, and disposal guidance

Follow applicable safety procedures and environmental regulations when handling, replacing, or disposing of internal cable assemblies. E-waste rules vary by jurisdiction, and compliance with local disposal policies for electronic components is required.

  • Adhere to ESD and electrical safety standards when installing or removing internal cables.
  • Dispose of damaged or end-of-life harnesses through approved electronic waste channels.
  • Document disposal in asset logs if local policy requires traceability.

Comparative evaluations and variant considerations

For administrators managing mixed fleets and multiple HPE generations, recognizing differences between various fan harnesses prevents incorrect substitutions and clarifies inventory needs. Below are practical differentiators and recommended actions when harmonizing inventories of multiple chassis types.

Use cases, practical scenarios, and operational impact

The AH233-2002A harness appears in a variety of operational contexts. The real-world implications of choosing the correct cable range from improved uptime to simplified logistics for legacy hardware maintenance.

Data center operations and MTTR reduction

Quickly replacing a failed lower fan harness with a validated AH233-2002A reduces Mean Time To Repair (MTTR) and prevents cascading thermal events. Storing harnesses with clear labels and part numbers in a rack-level spare kit expedites repairs during off-hours or unstaffed periods.

Refurbishment and resale optimization

Refurbishers who replace worn harnesses with OEM or equivalent parts can increase the reliability and perceived value of used DL785 G5 units, allowing for better resale pricing and lower return rates.

Lab testing and R&D environments

Test benches and staging labs benefit from known-good harnesses to eliminate cables as a variable in stress tests, benchmarking, or failure analysis, ensuring test integrity and repeatability.

Features
Product/Item Condition:
Excellent Refurbished
ServerOrbit Replacement Warranty:
1 Year Warranty
Customer Reviews