Your go-to destination for cutting-edge server products

HPE N9X03A Store Virtual 3000 10Gb Short Range iSCSI SFP+ Transceiver.

N9X03A
* Product may have slight variations vs. image
Hover on image to enlarge

Brief Overview of N9X03A

HPE N9X03A Store Virtual 3000 10Gb Short Range iSCSI SFP+ Transceiver. Excellent Refurbished with 1 year replacement warranty

$282.15
$209.00
You save: $73.15 (26%)
Ask a question
Price in points: 209 points
+
Quote
Additional 7% discount at checkout
SKU/MPNN9X03AAvailability✅ In StockProcessing TimeUsually ships same day ManufacturerHPE Manufacturer WarrantyNone Product/Item ConditionExcellent Refurbished ServerOrbit Replacement Warranty1 Year Warranty
Google Top Quality Store Customer Reviews
Our Advantages
Payment Options
  • — Visa, MasterCard, Discover, and Amex
  • — JCB, Diners Club, UnionPay
  • — PayPal, ACH/Bank Transfer (11% Off)
  • — Apple Pay, Amazon Pay, Google Pay
  • — Buy Now, Pay Later - Affirm, Afterpay
  • — GOV/EDU/Institutions PO's Accepted 
  • — Invoices
Delivery
  • — Deliver Anywhere
  • — Express Delivery in the USA and Worldwide
  • — Ship to -APO -FPO
  • For USA - Free Ground Shipping
  • — Worldwide - from $30
Description

Comprehensive Details of HPE N9X03A StoreVirtual 3000 10Gb iSCSI SFP+ Transceiver

The HPE N9X03A StoreVirtual 3000 iSCSI SFP+ module delivers reliable 10Gb data transmission, designed for enterprise-grade storage environments requiring efficiency, speed, and scalability. Built for the StoreVirtual 3000 platform, this plug-in solution ensures seamless integration, optimal performance, and long-lasting durability.

Core Specifications:

  • Brand: Hewlett Packard Enterprise (HPE)
  • Model: N9X03A
  • Product Name: HPE SV3000 10Gb 2-pack iSCSI SFP Transceiver
  • Interface Type: iSCSI networking
  • Data Speed: 10 Gigabits per second
  • Port Count: Dual connectivity support
  • Connector Format: SFP plug-in
  • Form Factor: Compact module design

Connectivity and Compatibility

Engineered to support advanced networking infrastructures, this transceiver ensures maximum interoperability with HPE StoreVirtual 3000 systems. By supporting Ethernet and iSCSI protocols, it provides consistent network reliability while enabling enterprises to scale operations effortlessly.

Key Highlights

  • Hot-swappable for simplified installation and replacement
  • Seamless compatibility with enterprise-grade HPE storage arrays
  • Supports maximum distance of 300 meters with multimode fiber
  • Utilizes 850nm wavelength for stable transmission

Durability and Environmental Tolerance

With optimized environmental conditions, the HPE N9X03A guarantees stable operation even under demanding data center workloads.

Environmental Specifications

  • Temperature Range: 0°C to 70°C (32°F to 158°F)
  • Humidity Range: 10% to 85% non-condensing
  • Power Consumption: Maximum 1W

Performance Standards and Certifications

Built to comply with industry-recognized standards, this module ensures safe and eco-friendly usage without compromising functionality.

  • Compliance: RoHS certified
  • Supported Protocols: Ethernet
  • Status Indicators: Link and activity monitoring LEDs

Physical Characteristics

Designed with compactness in mind, the transceiver easily integrates into high-density networking setups without consuming excess space.

Dimensions

  • Size: 2.2 x 5.2 x 1.2 cm
  • Form Factor: Plug-in modular design
  • Lightweight and portable for quick deployment
Ideal Use Cases
  • Large-scale data centers requiring high bandwidth
  • Businesses adopting HPE StoreVirtual 3000 platforms
  • IT environments needing reliable storage-to-network connectivity

Why this transceiver matters for storage networks

Modern storage clusters and SANs demand deterministic latency, consistent packet delivery and the ability to push large block I/O across converged networks. The N9X03A is aimed at that use case: 10 Gbps line rate, SFP+ form factor, and iSCSI protocol compatibility make it a straightforward choice for scaling StoreVirtual 3000 arrays or retrofitting 10G connectivity into existing storage racks without complex optical transceiver validation. Its short-range fiber profile makes it ideal for intra-data-center links (rack-to-rack or adjacent-rack connections) where multimode fiber is already installed.

Primary use cases

  • Connecting StoreVirtual 3000 controllers to 10G iSCSI switch ports
  • High-speed replication between clustered storage nodes
  • Upgrading server or HBA ports to 10Gb/s iSCSI without replacing switch fabric
  • Short-reach fiber interconnects in dense rack deployments where copper is not preferred

Physical and optical details

The N9X03A uses an 850 nm vertical-cavity surface-emitting laser (VCSEL) optimized for multimode fiber (MMF). Typical SR reach characteristics for 10GBase-SR optics are determined by fiber grade (OM1/OM2/OM3/OM4) and cabling quality; this transceiver is intended for short-range links commonly implemented on OM3/OM4 fiber within the data center. When planning links, assume standard 10GBase-SR behavior (for example: tens of meters on older OM1/OM2 and up to a few hundred meters on OM3/OM4 — consult your cabling vendor and test results for exact reach).

Compatibility & platform considerations

This module is branded and positioned specifically for HPE StoreVirtual 3000 series storage arrays and associated HPE networking equipment. Many enterprise buyers also deploy the N9X03A in mixed environments where the switch or server port accepts MSA-compliant SFP+ optics. That said, some vendors apply transceiver locking or firmware checks; always confirm compatibility with the target host (server NIC, HBA or switch) before purchase and consider vendor-recommended optics lists for mission-critical infrastructure. 

Interoperability checklist

  1. Verify the physical SFP+ slot accepts third-party optics or that the vendor explicitly lists N9X03A as supported.
  2. Confirm the host firmware and HBA driver versions are current — some interoperability issues are resolved in firmware updates.
  3. Match fiber type (OM3/OM4) and rated cable distance to the transceiver’s SR profile.
  4. Test link stability using loopback or a traffic generator before moving into production.

Deployment planning: best practices for storage teams

Successful deployment of N9X03A transceivers in storage networks depends on planning physical topology, validating cabling, and spacing for cooling and serviceability. Below are practical recommendations that streamline deployment and reduce risk.

Site survey and cabling verification

  • Run an optical loss budget for each link and validate with an optical power meter or OTDR where possible.
  • Prefer OM3 or OM4 multimode fiber for 10GBase-SR deployments to ensure predictable performance and future headroom.
  • Label both ends of every fiber run and include an audit record of connector types and cable lengths.

Compatibility testing and burn-in

Before placing transceivers in production, perform a 24–72 hour burn-in under typical traffic loads and monitor error counters (FEC, CRC, link drops) and temperature. If deploying in pairs for redundancy (common in StoreVirtual clusters), test failover and replication tasks while measuring latency and throughput to ensure no single-point issues exist. Vendors that resell the N9X03A often provide limited warranties and return windows — retain proof of purchase and test serial numbers immediately. :contentReference[oaicite:6]{index=6}

Availability, packaging and procurement tips

The N9X03A is commonly offered through HPE channel partners and third-party resellers as new, refurbished or surplus inventory. It is frequently packaged as a 2-pack (two identical SFP+ modules) which aligns with the common practice of installing matched optics on both ends of a fiber run. Prices vary by condition and vendor; when sourcing, compare warranty terms, return policies and whether the modules ship with HPE part numbers and serial tags intact. :contentReference[oaicite:7]{index=7}

Performance, monitoring and troubleshooting

While the N9X03A is a straightforward optical module, storage administrators should include it in their monitoring and telemetry systems. Track optical power levels, temperature, symbol error rates and link up/down events. When problems occur, follow a methodical isolation process: swap with a known-good module, test the fiber with an OTDR or inspection scope, and verify the host port config and driver state. Keep spare transceivers on hand if uptime is critical. :contentReference[oaicite:8]{index=8}

Common troubleshooting scenarios

  • No link up: inspect duplex LC connectors for dirt, check fiber polarity and ensure both ends use SR-rated multimode fiber.
  • Intermittent errors: verify optical power levels, cable bends, and connector cleanliness (use approved fiber cleaning tools).
  • Speed negotiated at 1G instead of 10G: confirm the host port is enabled for 10G and not forced to 1G; check SFP+ compatibility notes.

Security, warranty & lifecycle considerations

For mission-critical infrastructure, lifecycle and support planning are as important as raw specs. Although the N9X03A is an HPE-branded part, buyers should confirm whether the transceiver is covered under HPE warranty when purchased through third-party channels (new vs refurbished distinction matters). Additionally, keep an eye on HPE product retirement notices for StoreVirtual lines and plan firmware and hardware end-of-life (EOL) transitions accordingly. If you require HPE support on interoperability issues, make sure to retain original part numbers and proof of purchase.

Features
Manufacturer Warranty:
None
Product/Item Condition:
Excellent Refurbished
ServerOrbit Replacement Warranty:
1 Year Warranty