Essential Technical Profile: Lenovo 36002293 PSU
Engineered for optimal performance, the Lenovo 36002293 is a 450-watt power supply module. This unit serves as the primary electrical foundation for compatible server systems, delivering stable and consistent power to critical components.
Primary Attributes and Server Compatibility
This power supply unit is characterized by its dedicated design and robust construction. Its principal purpose is to ensure seamless integration and flawless operation within its intended ecosystem.
Manufacturer Part Number and Brand
- OEM Part Code: 36002293
- Brand: Lenovo
Technical Specifications
Electrical Specifications
- Rated output: 450 Watts continuous
- Input voltage range: 100–240 VAC (auto-sensing) for universal global use
- Input frequency: 50–60 Hz
- Inrush current behavior and hold-up time — relevant for UPS sizing and rack PDU planning
- Ripple and noise specifications — important for sensitive storage and I/O cards
Designed System Integration and Form Factor
This component boasts a proprietary form factor, meticulously crafted to install perfectly into the designated server chassis. This ensures a secure physical fit and eliminates compatibility concerns with non-certified systems.
Exclusive Hardware Synchronization
- Purpose-built for the Lenovo ThinkServer TS430 platform.
- Proprietary chassis design guarantees a perfect physical fit.
Electrical Specifications and Performance Metrics
The unit provides a maximum sustained power output of 450 watts. This capacity is engineered to support the processing, memory, and storage demands of the host server under typical operational loads.
Input Voltage Range and Efficiency Classification
- AC Input Range: 100-240V, enabling deployment in various regional electrical environments.
- Energy Efficiency: Achieves high efficiency ratings, potentially meeting 80 Plus Bronze or Silver benchmarks, minimizing energy waste and reducing heat generation.
Output Delivery and Connector Interface
Features a tailored set of connectors specifically arranged for the target server. This includes all necessary cables for the system board, peripherals, and drives, ensuring a clean and direct power pathway.
Intended Systems and Compatibility
These power supplies are specifically designed for Lenovo ThinkServer TS430 tower servers, matching the TS430 chassis cutouts, mounting points, and internal cable harness. The category includes:
- Genuine Lenovo 36002293 OEM 450W modules (preferred for certified warranty compliance)
- Manufacturers-tested aftermarket equivalents (with verified electrical and mechanical compatibility)
- Refurbished and reconditioned modules — often cost-effective for legacy fleets
- Accessory kits — harnesses, display adapters, and retention hardware for retrofitted installations
Buyers should confirm part numbers, BIOS requirements, and firmware compatibility when mixing OEM and third-party components. While a replacement physically fits a TS430, subtle firmware or monitoring differences may affect server management software reporting (IPMI, IMM, or vendor-specific health sensors); the products in this category explicitly document those differences.
Key Features and Functional Highlights
Reliable 450W Power Delivery
The 450W rating is sized to support typical TS430 configurations: single CPUs with moderate core counts, multiple spinning or SSD storage devices, mezzanine cards, and standard memory population. The category describes steady-state and transient headroom characteristics so IT teams can assess whether a 450W supply meets peak load conditions (disk spin-up, RAID rebuilds, or CPU turbo bursts).
Form Factor and Connector Layout
Mechanical fit is crucial: these modules match the TS430 mounting form, screw locations, and rear exhaust layout to maintain chassis airflow. Connector types include motherboard power headers, auxiliary CPU/PCIe power leads (if present), and internal fan power interfaces. The category details cable lengths, latch styles, and keyed connectors to prevent incorrect installation and to speed up swaps in service windows.
Efficiency and Thermal Performance
Efficiency metrics (typically presented as percentage at 20%/50%/100% load points) are part of each product listing. Higher efficiency reduces heat output, lowers electricity costs, and improves component longevity. Thermal performance is specified under server airflow conditions (CFM or topology notes), allowing comparison of OEM vs. aftermarket options for noisy vs. quiet deployments.
Safety, Protections & Standards
The category lists over-current, over-voltage, short-circuit, and over-temperature protections. Certifications often include UL, CE, FCC Class B for EMI, and RoHS compliance. Some modules provide additional surge tolerance or transient suppression features beneficial in unstable electrical environments.
Mechanical & Environmental
- Dimensions and weight to ensure chassis fit
- Operating temperature range (typical 0°C to 40°C) and storage temperature range
- Shock and vibration tolerances for shipping and rack environments
Performance Considerations and Sizing Advice
Calculating Actual Power Needs
Server power draw depends on CPU TDP, number and type of drives (HDD vs. SSD), DIMM population and speed, and expansion cards. The category provides guidance on estimating real-world consumption: start with vendor TDP and add 10–20% for peak transients. For mixed loads, a 450W supply suits many standard TS430 builds; however, heavily populated storage configurations or added GPU/accelerator cards may exceed safe margins.
Redundancy and Load Balancing
If redundancy is required, the category includes compatible dual-supply configurations and explains how the system balances load across supplies. Guidance on expected behavior during a single-supply failure (failover indicators, audible alarms, and management traps) helps operations plan the replacement SLA to avoid data loss or unplanned downtime.
Burn-In and QA Testing
Listings often indicate whether modules underwent 24–72 hour burn-in, thermal cycling, and full-load testing. These processes reduce early-life failures and are especially important for refurbished units; purchasers in production environments should prefer units with documented QA evidence.
Safety, Compliance & Environmental Concerns
Regulatory Compliance
Products in this category comply with regional safety and electromagnetic standards. For international procurement teams, the product pages clearly document which certifications are present (e.g., UL/cUL, CE, EAC). For environments with strict electromagnetic or emissions requirements, Class B certification and verified conducted emissions data is supplied.
Stocking and Spares Strategy
For operational resilience, the category recommends stocking spares based on fleet size and MTTR targets—commonly one spare per 10–20 servers for critical environments. A parts rotation policy, periodic functional testing, and secure storage practices are recommended to prevent degraded spare performance.
Use Cases & Deployment Scenarios
Small Business and Branch Office
TS430 servers in SMB settings often run file/print, virtualization for small clusters, or application services. The 450W PSU category supports common configurations without the cost or complexity of enterprise redundant supplies, while offering an easy upgrade path should loads increase.
Edge and Remote Sites
For remote deployments, the emphasis is on long life, wide input voltage tolerance, and documentation for remote hands technicians. Stocking spare Lenovo 36002293 modules in regional depots can reduce travel-related maintenance costs.
Repair Shops and Refurbishers
Repair centers benefit from bulk spare kits, diagnostic LED guides, and compatibility matrices included with category listings. Refurbishers should look for graded units (A/B) with test logs to ensure resale quality.
Cross-sell, Upgrades & Complementary Items
Complementary products enhance the value of a PSU purchase: server cooling upgrades, cable management brackets, replacement chassis fans, UPS units sized with PSU inrush and hold-up times in mind, and extended support contracts. Listings often bundle power supplies with fast-shipment RMA options and firmware updates to ensure monitoring compatibility with Lenovo XClarity or similar management tools.
Label & Serial Number Decoding
Guidance on reading manufacturer labels — date codes, serial numbers, and revision IDs — helps operations teams track lifecycle, maintain asset records, and determine warranty eligibility during RMA requests.
Storage, Handling & Inventory Best Practices
Store replacement modules in anti-static packaging, in temperature-controlled locations away from dust and humidity. Rotate stock occasionally to perform functional checks. Maintain an inventory with part numbers, purchase dates, and test status to streamline RMA claims and lifecycle replacement planning.